Description: | The site operator inadvertently entered incorrect surface MET values for the subject
sounding. Although he caught the error soon after launch and reported it immediately, it was
too late to correct. The following table shows the incorrect (present in the file) and
correct values.
Incorrect Correct
Pressure 1000.0 973.9
Temperature 35.0 30.5
Relative Humidity 27 30
The incorrect values for surface temperature and relative humidity will not affect the
other values in the sounding. The incorrect surface pressure will, however, affect the
altitude calculation throughout the sounding. |