Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/06/1994 | 0000 | 01/23/1996 | 2359 | Suspect |
Subject: | SGP/SIROS - wrong units for broadband irradiance |
DataStreams: | sgpsirosE24.a1, sgpsirosE1.a1, sgpsirosE18.a1, sgpsirosE9.a1, sgpsirosE4.a1, sgpsirosE20.a1, sgpsirosE12.a1, sgpsirosE8.a1, sgpsirosE7.a1, sgpsirosE13.a1, sgpsirosE10.a1, sgpsirosE15.a1, sgpsirosE3.a1, sgpsirosE22.a1, sgpsirosE16.a1, sgpsirosE11.a1 |
Description: | Headers for SIROS, give the units for broadband irradiance as 'watts per square meter' (w/m^2). However, the units are really 'counts'. The fields affected are: 'hemisp_broadband:units' 'diffuse_hemisp_broadband:units' 'direct_norm_broadband:units' This problem existed since the beginning of the data streams, and was corrected on 1/23/96. |
Suggestions: | |
Measurements: | sgpsirosE11.a1: more
sgpsirosE3.a1: more sgpsirosE12.a1: more sgpsirosE1.a1: more sgpsirosE10.a1: more sgpsirosE4.a1: more sgpsirosE13.a1: more sgpsirosE15.a1: more sgpsirosE16.a1: more sgpsirosE22.a1: more sgpsirosE20.a1: more sgpsirosE18.a1: more sgpsirosE24.a1: more sgpsirosE9.a1: more sgpsirosE8.a1: more sgpsirosE7.a1: more |