Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/12/1995 | 0000 | 10/13/1995 | 1230 | Incorrect |
Subject: | SGP/EBBR/E26 - Net Radiometer Dome Punctured |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The upper dome of the net radiometer was punctured sometime between the PM visits of September 12 and 26, 1995. After the puncture, water collected in the top hemisphere. The water was removed on September 26, but a replacement dome was not available. The dome was replaced during the PM visit on October 13, 1995. The puncture and water did not result in obviously incorrect data. I cannot tell when the puncture occurred from the data. The data, particularly during the two weeks between September 12 and 26, 1995, should be considered suspect. Suspect net radiation data results in the latent heat flux and sensible heat flux also being suspect. Suspect data then includes: 5 minute: q 15 minute: mv_q 30 minute: q, e, h. |
Suggestions: | |
Measurements: | sgp5ebbrE26.b1: more
sgp15ebbrE26.b1: more sgp30ebbrE26.b1: more |