Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/24/1995 | 1930 | 05/28/1995 | 0100 | Incorrect |
05/28/1995 | 0130 | 06/01/1995 | 1630 | Incorrect |
06/05/1995 | 1730 | 06/05/1995 | 1900 | Incorrect |
05/09/1995 | 1705 | 05/16/1995 | 1900 | Incorrect |
06/06/1995 | 1530 | 06/06/1995 | 1900 | Incorrect |
Subject: | SGP/EBBR/E26 - Right Air Temperature Malfunction |
DataStreams: | sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1 |
Description: | The right air temperature probe malfunctioned continuously during the periods of time indicated above as continuous. On May 16, 1995, by 1900 GMT, the probe was replaced (old S/N 92007, new S/N 92013). There was a complete loss of data between 1200 and 1900 GMT as Site Operations repaired a corroded battery terminal. For several days the right air temperature probe worked well. However, between May 24 and 28, the right air temperature probe malfunctioned continuously again. The right air temperature probe malfunctioned intermittently between May 28 and June 1, as well as during short periods on June 5 and 6. The cause of these latter periods is unknown; the time periods do not correspond with any Site Operations activities. During the intermittent periods the data that is not offscale should be viewed as questionable, as it is not always easy to detect what effect the malfunction might have had on that data. The malfunction of the right air temperature probe results in incorrect Bowen ratio, sensible heat flux, and latent heat flux during the periods indicated. The data values that are affected are: 5 minute: tair_top, tair_bot 15 minute: tair_r 30 minute: tair_top, tair_bot, bowen, e, h. |
Suggestions: | |
Measurements: | sgp5ebbrE26.b1: more
sgp15ebbrE26.b1: more sgp30ebbrE26.b1: more |