Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/22/1994 | 1200 | 08/04/1994 | 1600 | Suspect |
Subject: | SGP/EBBR/E12 - Stopped Ventilation Fan |
DataStreams: | sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1 |
Description: | On August 4, 1994, a site operator discovered the ventilation fan of the EBBR to be stopped; the fan guard was clogged with animal remains. Inspection of the EBBR data from Pawhuska, OK, E12 indicates that this condition occurred from July 22 through August 4. Lack of ventilation of the temperature and relative humidity sensors attached to the AEM results in questionable measurements of air temperature, relative humidity, and all quantities calculated from them, including sensible and latent heat fluxes. The quantities that are questionable for the period indicated are: 5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, and vp_bot 15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l 30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot, bowen, e, h |
Suggestions: | |
Measurements: | sgp15ebbrE12.b1: more
sgp5ebbrE12.b1: more sgp30ebbrE12.b1: more |