Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/06/2006 | 0000 | 04/12/2007 | 2359 | Incorrect |
Subject: | SGP/RADFLUXANAL/E22 - Incorrect calibration coefficient |
DataStreams: | sgpradflux1longE22.c2 |
Description: | NIP (short_direct_normal) 29541E6 had an incorrect calibration coefficient in the logger program. The correct calibration should have been 126.67 [W/m2/mV] instead of 128.97. The correct calibration was calculated as NIPIrr(cor) = NIPIrr(orig) * (126.67/128.97) = NIP(orig) * 0.982166 The SIRS is input into the qcrad1long.c2 which is input to the radflux1long.c2. Once the qcrad1long.c2 has been reprocessed for this issue, the radflux1long will need to be reprocessed. |
Suggestions: | Do not use data |
Measurements: | sgpradflux1longE22.c2: more
|