Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/10/2008 | 0700 | 10/29/2008 | 1700 | Incorrect |
Subject: | SGP/SWATS/E3 - Sensor failure, 60cm E |
DataStreams: | sgpswatsE3.b1 |
Description: | The temperature rise readings from the 60-cm depth on the east profile (trise_E) were incorrect. This problem also causes the matric potential (soilwatpot_E) and water content (watcont_E) data for the 60-cm depth to be incorrect. The sensor began to behave erratically at 7:00 GMT on 07/10/2008 before an apparent failure at 10:00 GMT on 08/07/2008. Maintenance on 10/29 corrected the problem. Values of tsoil_E at the 60 cm depth are not impacted by this problem. |
Suggestions: | Use 60cm W measurements |
Measurements: | sgpswatsE3.b1: more
|