Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/28/2007 | 0140 | 10/11/2007 | 1730 | Suspect |
Subject: | SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | The left Thum (temperature of the humidity sensor chamber) measurement was incorrect at times, affecting several measurements, including the sensible and latent heat fluxes. |
Suggestions: | |
Measurements: | sgp5ebbrE26.b1: more
sgp15ebbrE26.b1: more sgp30ebbrE26.b1: more |