Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/24/2006 | 1400 | 08/02/2006 | 1320 | Suspect |
Subject: | SGP/SMOS/E21 - Wind Monitor Impacting Bird Spikes |
DataStreams: | sgp1smosE21.b1, sgp30smosE21.b1, sgp1440smosE21.b1 |
Description: | The wind direction is flatlining and wind speed occasionally does not compare well with co-located ECOR. Problems with the height of the mount caused the vane to impact the bird deterrent spikes and "catch". Symptoms appear as winds coming out of a 255 to 270 direction for long period of times. The wind speed values are also affected as the wind monitor is no longer normal to the wind direction. |
Suggestions: | Use the co-located ECOR data when wind directions are flat-lined in the 255 to 270 direction. |
Measurements: | sgp1smosE21.b1: more