Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/17/2005 | 1630 | 08/27/2005 | 1930 | Incorrect |
Subject: | SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredt |
DataStreams: | sgp5ebbrE27.b1, sgp30ebbrE27.b1, sgp15ebbrE27.b1 |
Description: | Residual Moisture left in the top dome of the net radiometer after the 8/17/05 servicing caused the net radiation measurements to be biased low, and resulting in sensible and latent heat flux being low also. |
Suggestions: | |
Measurements: | sgp5ebbrE27.b1: more
sgp15ebbrE27.b1: more sgp30ebbrE27.b1: more |