Description: | Power to the Tip tower and Groundrad was disconnected briefly while ground resistance
measurements were made.
The following comments are from Inst. Mentor Tom Stoffel:
The longwave and shortwave irradiances from GNDRAD were not effected by the
temporary power disconnect. Data are good. This would have only stopped
the ventilators for a brief time and the data do not show any signs of poor
instrument responses.
The "sfc_ir_temp" data were, however, impacted during the brief (2
readings?) interval. |