Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/01/2005 | 1132 | 08/01/2005 | 1316 | Incorrect |
Subject: | SGP/SONDE/C1 - Bad T/RH and surface P. |
DataStreams: | sgpsonderawC1.00, sgpsondewnpnC1.b1, sgpsondeC1.00 |
Description: | Apparently multiple failures. The radiosonde temperature sensor broke on launch causing an approximate 35 degC negative offset and as a result, the RH is incorrect. Furthermore, it appears that the pressure sensor was off by approximately 4 hPa, though this would not affect the altitude calculation, the absolute pressure is wrong. |
Suggestions: | Do not use Temperature and Relative Humidity data. Correct pressure data before using. |
Measurements: | sgpsonderawC1.00: more
sgpsondeC1.00: more sgpsondewnpnC1.b1: more |