Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/04/2005 | 0200 | 06/30/2005 | 1545 | Suspect |
Subject: | SGP/SMOS/E6 - RH Sensor failure |
DataStreams: | sgp30smosE6.b1, sgp1smosE6.b1, sgp1440smosE6.b1 |
Description: | The RH readings on the SMOS dropped to zero or became very noisy during rain or moist conditions. The sensor was replaced. |
Suggestions: | Use neighboring stations RH%. |
Measurements: | sgp1440smosE6.b1: more
sgp30smosE6.b1: more sgp1smosE6.b1: more |