Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/13/2003 | 0000 | 11/26/2003 | 2300 | Suspect |
Subject: | SGP/EBBR/E12 - Pressure Sensor Measurement Scales With Battery Voltage |
DataStreams: | sgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1 |
Description: | The barometer output was scaling with supply voltage (i.e. it followed the charging of the battery by the solar panel). NOTE: The barometer was replaced later than the end date of this DQR. Why the problem ended on 26 Nov 2003 is unclear; there was no site ops intervention on that date. The problem did not affect the sensible and latent heat flux calculations beyond the expected system error. |
Suggestions: | No adjustments to the sensible and latent heat flux data are needed. |
Measurements: | sgp15ebbrE12.b1: more
sgp5ebbrE12.b1: more sgp30ebbrE12.b1: more |