Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/11/2003 | 0438 | 11/18/2003 | 2200 | Incorrect |
Subject: | SGP/SIRS/E1 - Unknown - Downwelling shaded longwave measurement incorrect |
DataStreams: | sgpsirs20sE1.a0, sgpsirsE1.00, sgpsirsE1.b1 |
Description: | Downwelling longwave values were very noisy and out of range due to a missing PIR case temperature measurement. Faulty wiring to the case temperature thermistor on the downwelling longwave IR instrument (PIR) was the likely cause of the problem. On 11/18, the E1 tracker and associated instruments (direct shortwave -NIP, hemispheric shaded shortwave -8-48 and hemispheric shaded longwave - problem PIR) were moved to a new tracker stand. Rewiring the instrument corrected the problem. |
Suggestions: | Disregard this data |
Measurements: | sgpsirsE1.b1: more
sgpsirs20sE1.a0: more sgpsirsE1.00: more |