Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/13/2001 | 2002 | 03/21/2003 | 2024 | Incorrect |
Subject: | SGP/IRT25m/C1 - Reprocess: up_short_hemisp needs -1 multiplier |
DataStreams: | sgpirt25m20sC1.a0, sgpirt25mC1.a2, sgpirt25mC1.00, sgpirt25mC1.a1 |
Description: | The upwelling hemispheric shortwave measurement in the SGP.C1 IRT25m data streams for the time period noted requires a (-1) multiplier to correct for swapped connections at installation. |
Suggestions: | multiply by (-1) |
Measurements: | sgpirt25mC1.a1: more
sgpirt25mC1.00: more sgpirt25mC1.a2: more sgpirt25m20sC1.a0: more |