Description: | Soil moisture measurements from sets 2 and 5 were incorrect, leading to many other
incorrect measurements calculated using them.
Average soil heat flow, sensible heat flux, and latent heat flux are affected; these can
be recalculated using the remaining good sets of soil sensors as follows:
ave_shf = (g1 + g3 + g4)/3
e = -(q + ave_shf)/(1 + bowen)
h = -(q + e + ave_shf)
Note: D020717.6 reports Soil temperature sensor #3 was also bad during this
time, but for the very specific records affected by the soil moisture #2 and
#5 reporting incorrectly, soil temp #3 was okay. Therefore the equations
given are correct. |