Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/15/2001 | 2315 | 12/14/2001 | 2356 | Suspect |
Subject: | SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrect |
DataStreams: | sgp30ebbrE9.b1, sgp15ebbrE9.b1 |
Description: | Soil moisture probe #5 in the recalibrated unit installed on 5/11/01 has not been working all of the time. At times the measurement has been very large and incorrect. The indicated measurements are incorrect at those times. The data must be inspected to determine the times that have incorrect data. The sensible and latent heat fluxes can be recalculated by using soil sets 1, 2, 3, and 4 only in a recalculation of the energy budget. |
Suggestions: | Inspect data for times of incorrect data. Soil temperatures above 35 C or below -10 C are not likely at E9 |
Measurements: | sgp30ebbrE9.b1: more
sgp15ebbrE9.b1: more |