Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/23/2000 | 2330 | 06/24/2000 | 0100 | Incorrect |
Subject: | SGP/SONDE/C1 - Operator used wrong calibration tape |
DataStreams: | sgpsondeC1.a0, sgpsondeC1.00, sgpsondewrpnC1.00, sgpsondeC1.a1, sgpsondewrpnC1.a0, sgpsondewndcalcC1.c1, sgpsondewrpnC1.a1 |
Description: | It appears as if the operators had a problem with the original sounding and launched a second radiosonde. Apparently they used the calibration tape that came with the first radiosonde (serial number 943156405) in place of the one that was correct for the second radiosonde (sn 943156406) and all the data are bad after the first sample (surface values). |
Suggestions: | The data cannot be corrected. I would delete the whole file. |
Measurements: | sgpsondewrpnC1.a0: more
sgpsondewndcalcC1.c1: more sgpsondeC1.a0: more sgpsondeC1.a1: more sgpsondeC1.00: more sgpsondewrpnC1.a1: more sgpsondewrpnC1.00: more |