Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
06/30/2014 | 1908 | 07/03/2014 | 1607 | Incorrect |
Subject: | SGP/MFRSR/E13 - Logger time not correct |
DataStreams: | sgpmfrsrlangleyE13.c1, sgpmfrsrE13.b1, sgpmfrsrE13.a0, sgpmfrsrlangplotE13.c1, sgpmfrsrE13.00 |
Description: | A network upgrade inadvertently caused the time to be set incorrectly. With the time significantly off the instrument was not shading properly. Because the time was not correct, no data are usable. Do not use data covered by this DQR. |
Suggestions: | Look to the NIMFR or the C1 MFRSR instead |
Measurements: | sgpmfrsrlangleyE13.c1:
sgpmfrsrlangplotE13.c1:
sgpmfrsrE13.b1:
sgpmfrsrE13.a0:
sgpmfrsrE13.00:
|