Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/23/2011 | 1300 | 10/16/2011 | 0423 | Incorrect |
Subject: | GAN/MFRSR/M1 - Incorrect hardware configuration |
DataStreams: | ganmfrsrM1.b1, ganmfrsrM1.a0, ganmfrsrauxM1.a0 |
Description: | When the instrument was set up it was discovered the equatorial motor mount was not compatible with the mid-latitude stand. To resolve the issue, either the head needed to be lowered 2", or the motor raised 2". After some consideration, it was decided the best path forward was to have a custom equatorial mount built that is compatible with mid-latitude stands. One was built by the NOAA machine shop in Boulder, and hand carried to the instrument location. The bracket was installed on 10/16. |
Suggestions: | |
Measurements: | ganmfrsrM1.b1: more
ganmfrsrM1.a0: more ganmfrsrauxM1.a0: more |