Subject: | SGP/RWP/I3 - no usable moments data available |
DataStreams: | sgp915rwpwindmomI3.a0, sgp915rwptempmomI3.a0
|
Description: | When the upgrade to the Central Facility rwp was installed, the interpretation of the
configuration file changed such that it became necessary to explicitly require that moments
data be saved within the raw spectral data file. Previously this was not true. The
ingest operates in such a way that it just goes a certain number of bytes into the spectral
data and takes the following section. Thus bogus moments data files were bing ingested
that had essentially no usable information insofar as moments data are concerned. Thus
there are no usable moments data files from this time period. At this time I have not been
able to determine a method to recreate the raw moments files from the spectral data in
any straightforward manner that would result in files with the precise format as presently used. |
Suggestions: | the moments can be calculated directly from the spectral data (the zeroth, first, and
second moments) |
Measurements: | sgp915rwptempmomI3.a0: - lon
- specw
- time_offset
- height
- snr
- virtual_temp
- sspecw
- alt
- mdf
- base_time
- smdf
- sampr
- noise
- ssnr
- lat
- rgs
more
sgp915rwpwindmomI3.a0: - spcavetime
- snr
- vband
- pcbits
- ncoh
- specw
- prf
- nheight
- height_t
- sitime
- tditime
- alt
- ipp
- noise
- sampr
- dly
- elevation
- mdf
- vsr
- nspc
- rgl
- beam
- oband
- range_gate
- rgs
- bswitch
- lat
- time_offset
- plen
- lon
- rgf
- base_time
more
|