Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
12/12/2001 | 1915 | 12/12/2001 | 2031 | Incorrect |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #3 Incorrect During Sensor Changeout |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #3 measurements were incorrect during it's replacement. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g5)/2 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) Note: during the time period referenced here, soil heat flow #4 and #2 were also incorrect. This quality information is documented in D020717.46, D020717.47 and D020726.1. |
Suggestions: | |
Measurements: | sgp30ebbrE20.b1: more
|