Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/01/2001 | 0000 | 07/31/2001 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated Data Quality - July 2001 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the July 2001 Oklahoma Mesonet data. Notes: Northwest and southwest Oklahoma were the hot spots of the state during July. Average 1800 UTC temperatures in those areas were over 36 C (97 F). The 1800 UTC pressure data revealed corresponding localized areas of low pressure (heat lows) in those same areas. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #5772 STIL Replaced bad sensor #5950 BRIS Replaced bad sensor WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: #5898 VANO Initial install of barometer SRAD Current: None Added: None Resolved: #5927 MARS Replaced sensor with high bias #6002 BUTL Replaced sensor with low bias RAIN Current: #6006 GOOD Soil moisture detected rainfall, but gauge did not Added: None Resolved: #5778 STIL Fixed double-counting gauge TA9M Current: None Added: None Resolved: #5658 MIAM Tightened wires to sensor WS2M Current: None Added: None Resolved: #5870 WEBB Replaced sensor with noisy bearings #5877 NEWK Replaced sensor with high starting threshold #5857 MADI Replaced dead sensor TS10 Current: None Added: None Resolved: None TB10 Current: None Added: None Resolved: #5885 DURA Tightened wire to correct erratic data TS05 Current: #5756 SLAP Sod is consistently warmer than bare plot Added: None Resolved: #5858 HOLL Corrected erosion problem TB05 Current: #5859 ARDM Data suggests sensor is sticking out of ground Added: None Resolved: #5859 ARDM Replaced sensor with high bias TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #5983 A133 Replaced sensor with high bias RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: #5909 A166 Replaced defective sensor #5966 A130 Replaced sensor with 6 C warm bias TS10 Current: #6000 A148 Sensor spiking to 50 C #6001 A125 Sensor spiking to 70 C Added: None Resolved: #5926 A159 Replaced gopher-damaged sensor #5910 A125 Replaced defective sensor TS15 Current: None Added: None Resolved: #5956 A159 Replaced gopher-damaged sensor #5963 A125 Replaced defective sensor #5965 A155 Replaced defective sensor TS30 Current: #5998 A130 Sensor dipping below 0 C #5999 A154 Sensor has a 10 C cool bias #6004 A122 Sensor reporting erratically and out of range Added: None Resolved: #5726 A135 Replaced defective sensor #5717 A134 Replaced defective sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |