Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
01/01/2001 | 0000 | 01/31/2001 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated Data Quality -January 2001 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the January 2001 Oklahoma Mesonet data. A major ice storm took place from January 28-30 across the northwest one-third of Oklahoma. The wind sensors became frozen at over 40 stations. Several occurrences in which soil temperature sensors have "heaved" themselves out of the ground have been noted by techs recently. After analyzing the soil temperature data for January, it appears that 9 additional stations may be having the same problem. Trouble tickets have been issued so that the suspect sites can be visited during this coming month. The unusually wet and cold winter is likely to blame. =============================================================== TAIR Current: None Added: None Resolved: None RELH Current: #5355 ERIC Sensor frequently drops to 0% Added: None Resolved: #5332 MEDI Replaced sensor with suspected 5% high bias WDIR Current: None Added: None Resolved: #5344 SKIA Replaced sensor stuck at 360 degrees WSPD Current: None Added: None Resolved: #5405 PAUL Replaced suspect sensor PRES Current: None Added: None Resolved: #5403 VINI Replaced barometer reporting +300 mb high bias SRAD Current: #5072 KETC Monthly QA indicates 5-10% high bias #5159 FAIR Sensor stuck at 0 Added: #5394 SEIL Sensor reporting 80% low Resolved: None RAIN Current: #5397 MEDF Gauge stuck at 0 during precip event Added: None Resolved: #5351 STIL Replaced gauge with bad switch #5396 NORM Replaced suspect gauge #5398 CLOU Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TB10 Current: #5402 MAYR 3 C cool bias Added: None Resolved: None TS05 Current: #5194 FAIR 5 C cool bias Added: None Resolved: None TB05 Current: #5416 REDR Possible erosion causing TB05 to drop well below freezing #5419 MARS Possible erosion causing TB05 to drop well below freezing Added: #5454 BLAC Possible erosion #5455 KING Possible erosion #5456 OKMU Possible erosion #5457 PRYO Possible erosion #5458 FORA Possible erosion #5459 TAHL Possible erosion Resolved: #5215 PUTN Repaired lose wire on mux TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #5395 A150 Repaired gauge by adjusting switch TS05 Current: None Added: #5453 A165 Possible erosion Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |