Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/01/2000 | 0000 | 10/31/2000 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated Data Quality - October 2000 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the October 2000 Oklahoma Mesonet data. TAIR Current: #5323 TIPT Sensor has 6 C high bias Added: None Resolved: None RELH Current: #5293 CATO Reporting 105% or higher #5316 WEBB Reporting 40% low bias Added: #5332 MEDI Monthly QA indicates 5% high bias Resolved: #5264 WEBB Replaced sensor with 5-10% high bias WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: None RAIN Current: #5297 BREC Under-reported rain event Added: None Resolved: #5272 BLAC Replaced bad switch #5277 STIL Gauge checked and no problem found after apparent under-reporting #5278 BRIS Removed spider web that prevented gauge from tipping #5296 KETC Replaced bad gauge #5314 ACME Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset #5281 FTCB Stuck at -273.1 C Added: None Resolved: #5279 BIXB Sensor found to have 1 C cool bias TB10 Current: #5216 PUTN Sensor erratic and dropping to as low as -17.2 C #5282 FTCB Stuck at -273.1 Added: None Resolved: #5261 WEST Repaired excitation wire TS05 Current: #5194 FAIR 5 C cool bias #5283 FTCB Stuck at -273.1 C Added: None Resolved: #5262 BRIS Sensor found to have 5 C cool bias #5263 BIXB Sensor found to have 2 C warm bias TB05 Current: #5215 PUTN Sensor erratic and dropping to as low as -87.5 C #5284 FTCB Stuck at -273.1 C Added: None Resolved: None TS30 Current: #5285 FTCB Stuck at -273.1 C #5301 WASH 9 C warm bias Added: None Resolved: #5273 APAC Replaced gopher-damaged sensor ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: None Added: None Resolved: #5180 A182 Replaced sensor with 2.5 C warm bias RELH Current: None Added: None Resolved: None SRAD Current: #5255 A151 Mesocomp found 6% difference #5294 A166 Stuck at 1 W/m^2 Added: None Resolved: None RAIN Current: #5319 A182 Dramatically over-estimates rainfall Added: #5325 A156 Gauge appears to have over- reported #5324 A151 Gauge stuck at 0 during rain event Resolved: #5295 A155 Replaced switch found to be double tipping #5232 A150 Replaced defective switch TS05 Current: None Added: None Resolved: #5243 A136 Replaced defective sensor #5265 A135 Replaced sensor reporting erratically TS10 Current: #5267 A111 Possible 3 C cool bias Added: None Resolved: #5266 A165 Corrected wiring problem TS15 Current: #5318 A167 Stuck at -90 C Added: None Resolved: None TS30 Current: None Added: None Resolved: #5157 A165 Replaced bad sensor ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |